Versa-Lam beams are strong throughout, engineered to support heavier loads, and provide longer spans than stock glulams (24F-V4) or dimensional lumber products.
When you need better performance, longer spans, and the best overall value, Versa-Lam® LVL delivers.
Versa-Lam laminated veneer lumber (LVL) beams and headers lead the industry in bending strength and E-value, offering better performance and longer spans. Versa-Lam LVL offers the best overall value across multiple widths and depths for residential, light commercial, or multifamily projects.
Heavy loads? No problem. Longer spans? Don’t give them a second thought. Versa-Lam LVL beams and headers are up to the task.
Versa-Lam LVL Benefits:
|
Versa-Lam beams are strong throughout, engineered to support heavier loads, and provide longer spans than stock glulams (24F-V4) or dimensional lumber products.
Versa-Lam LVL beams and headers won’t twist, shrink, or split, resulting in flatter, quieter floors and strong structures saving time while protecting reputations.
Precision cut into more than 18 standard sizes to match BCI and AJS Joists, with extra-wide widths that eliminate the need for bolting and nailing.
TECH NOTES - GENERAL ENGINEERING | > |
---|---|
Weights of Building Materals – GE-1 | View |
Brick Veneer Support on Wood – GE-2 | View |
Allowable Fastener Spacing & Design for BCI Joists and VERSA-LAM – GE-3 | View |
BCI / AJS Joist, VERSA-LAM & BOISE GLULAM Exterior Exposure Policy – GE-4 | View |
Required Separation Between Garage and Living Space Above – GE-5 | View |
Designing for Ceramic or Stone Tile Floor Finishes – GE-6 | View |
Rafter Bracing and Kneewall Loads – GE-8 | View |
Feet & Inches on a Regular Calculator – GE-9 | View |
Temperature and Moisture Content of Engineered Wood Products During Manufacturing – GE-10 | View |
High Slope Roofs – GE-12 | View |
Flame Spread Classifications and Corresponding Surface Treatments – GE-13 | View |
Formaldehyde & Engineered Wood Products – GE-15 | View |
Lateral Bracing of Joists and Beams – GE-16 | View |
Use of Engineered Wood Products in International Shipping Pallets and Packaging – GE-17 | View |
Wood Frame Garage Floor Design Guildlines – GE-19 | View |
Insect-Treated Engineered Wood Products Approved for Hawaii – GE-21 | View |
Design Load Considerations for Non-Load Bearing Partition Walls in Residental Construction – GE-22 | View |
Vertical Load Transfer over Bearings within BC FRAMER & BC CALC – GE-23 | View |
Use of Boise Cascade EWP for Concrete Formwork – GE-24 | View |
Pressure and Topical Applications and Treatments – GE-25 | View |
PreserveTech HW / Royal Pacific Industries Insect-Treated Engineered Wood Products for Hawaii – GE-26 | View |
Electrical Wiring Installation Horizontal Holes – GE-27 | View |
Installed Damaged Product – GE-28 | View |
TECH NOTES - VERSA-LAM LVL | > |
---|---|
Versa-Lam Allowable Hole Chart – LVL-1 | View |
Versa-Stud Allowable Nailing and Notching – LVL-2 | View |
Connecting Multiple-Ply Versa-Lam Beams – LVL-3 | View |
Connection of Side Point Loads to Triple 1 3/4" VERSA-LAM Beams – LVL-4 | View |
Cupping of VERSA-LAM Plies & Beams – LVL-5 | View |
Requirements for Use of Simpson Strong-Tie Connectors with Versa-LAM & Versa-Rim Products – LVL-6 | View |
Attachment fo Brick Lintel to Versa-Lam Beams – LVL-7 | View |
Connecting Multiple-Ply 1 3/4" VERSA-LAM Beams with Simpson Strong-Tie SDS Screws – LVL-8 | View |
Connecting Multiple-Ply 1 3/4" VERSA-LAM Beams with FastenMaster TrussLok Screws – LVL-9 | View |
Connection of Side Point Loads to Double 1 3/4" VERSA-LAM Beams – LVL-10 | View |
Versa-Lam® 2.0 3100 Column Table | View |
Simpson Strong-Tie® Connectors Parallel to Gluelines of Versa-Lam® Beams & Columns | View |
Versa-Lam® 2.0 3100 Column Table (Smaller Depth Columns) | View |
Connection of Side Point Loads to Quadruple 1 3/4" Versa-Lam® Beams | View |
Fire-Resistance Rating of Versa-Lam® LVL Columns | View |
Connecting Multiple-Ply Versa-Lam® Beams with Simpson Strong-Tie® SDW Strong-Drive Screws | View |
Alternate Power and Hand Driven Nailing of Multiple Ply 1 3/4" Wide Versa-Lam® Beams | View |
1 1/2" Versa-Lam® 1.7 2650 Joists Residential Floor Span Tables | View |
Concentrated Side Load Connection Multiple Ply VL BC Calc® | View |
Versa-Lam® Beam Allowable Reactions with End Bevel Cuts | View |
TECH NOTES - GENERAL ENGINEERING | > |
---|---|
Weights of Building Materals – GE-1 | View |
Brick Veneer Support on Wood – GE-2 | View |
Allowable Fastener Spacing & Design for BCI Joists and VERSA-LAM – GE-3 | View |
BCI / AJS Joist, VERSA-LAM & BOISE GLULAM Exterior Exposure Policy – GE-4 | View |
Required Separation Between Garage and Living Space Above – GE-5 | View |
Designing for Ceramic or Stone Tile Floor Finishes – GE-6 | View |
Rafter Bracing and Kneewall Loads – GE-8 | View |
Feet & Inches on a Regular Calculator – GE-9 | View |
Temperature and Moisture Content of Engineered Wood Products During Manufacturing – GE-10 | View |
High Slope Roofs – GE-12 | View |
Flame Spread Classifications and Corresponding Surface Treatments – GE-13 | View |
Formaldehyde & Engineered Wood Products – GE-15 | View |
Lateral Bracing of Joists and Beams – GE-16 | View |
Use of Engineered Wood Products in International Shipping Pallets and Packaging – GE-17 | View |
Wood Frame Garage Floor Design Guildlines – GE-19 | View |
Insect-Treated Engineered Wood Products Approved for Hawaii – GE-21 | View |
Design Load Considerations for Non-Load Bearing Partition Walls in Residental Construction – GE-22 | View |
Vertical Load Transfer over Bearings within BC FRAMER & BC CALC – GE-23 | View |
Use of Boise Cascade EWP for Concrete Formwork – GE-24 | View |
Pressure and Topical Applications and Treatments – GE-25 | View |
PreserveTech HW / Royal Pacific Industries Insect-Treated Engineered Wood Products for Hawaii – GE-26 | View |
Electrical Wiring Installation Horizontal Holes – GE-27 | View |
Installed Damaged Product – GE-28 | View |
TECH NOTES - VERSA-LAM LVL | > |
---|---|
Versa-Lam Allowable Hole Chart – LVL-1 | View |
Versa-Stud Allowable Nailing and Notching – LVL-2 | View |
Connecting Multiple-Ply Versa-Lam Beams – LVL-3 | View |
Connection of Side Point Loads to Triple 1 3/4" VERSA-LAM Beams – LVL-4 | View |
Cupping of VERSA-LAM Plies & Beams – LVL-5 | View |
Requirements for Use of Simpson Strong-Tie Connectors with Versa-LAM & Versa-Rim Products – LVL-6 | View |
Attachment fo Brick Lintel to Versa-Lam Beams – LVL-7 | View |
Connecting Multiple-Ply 1 3/4" VERSA-LAM Beams with Simpson Strong-Tie SDS Screws – LVL-8 | View |
Connecting Multiple-Ply 1 3/4" VERSA-LAM Beams with FastenMaster TrussLok Screws – LVL-9 | View |
Connection of Side Point Loads to Double 1 3/4" VERSA-LAM Beams – LVL-10 | View |
Versa-LAM 2.0 3100 Column Table – LVL-11 | View |
Installation of Simpson Strong-Tie Connectors Parallel to Gluelines of Versa-Lam Beams & Columns – LVL-12 | View |
Versa-LAM 2.0 3100 Column Table (Smaller Depth Columns) – LVL-13 | View |
Connection of Side Point Loads to Quadruple 1 3/4" VERSA-LAM Beams – LVL-14 | View |
Fire Resistance Rating of VERSA-LAM LVL Columns – LVL-15 | View |
Connecting Multiple-Ply VERSA-LAM Beams with Simpson Strong-Tie SDW Strong-Drive Screws – LVL-16 | View |
Alternate Power and Hand Driven Nailing of Multiple Ply 1 3/4" Wide VERSA-LAM Beams – LVL-17 | View |
1 1/2" VERSA-LAM 1.7 2650 Joists Residential Floor Span Tables – LVL-18 | View |
Concentrated Side Load Connection Multiple Ply VL BCCalc – LVL-19 | View |
VERSA-LAM® Beam Allowable Reactions with End Bevel Cuts – LVL-20 | View |
PRODUCT/SPECIFIER/TECHNICAL GUIDES | > |
---|---|
CANADA ENGLISH Versa-Lam® 2.1E 3100 East Specifier Guide | View |
CANADA ENGLISH Tall Wall Specifier Guide | View |
CANADA FRENCH Versa-Lam® 2.1E 3100 East Specifier Guide | View |
CANADA ENGLISH Install Guide | View |
CANADA ENGLISH Tall Wall Climatic Data Specifier Guide | View |
CANADA FRENCH Install Guide | View |
TECH NOTES - GENERAL ENGINEERING | > |
---|---|
Weights of Building Materals – GE(CAN)-1 | View |
Flame Spread and Fire Endurance: Surface Coatings – GE(CAN)-2 | View |
Allowable Nail Spacing & Designfor AJS® / BCI® Joists and Versa-L am® LVL – GE(CAN)-3 | View |
BCI / AJS Joist, VERSA-LAM & BOISE GLULAM Exterior Exposure Policy – GE(CAN)-4 | View |
Joist Ceiling Framing Over an Indoor Pool – GE(CAN)-5 | View |
Formaldehyde & Engineered Wood Products – GE(CAN)-15 | View |
Lateral Bracing of Joists and Beams – GE(CAN)-16 | View |
Vertical Load Transfer over Bearings within BC FRAMER & BC CALC – GE(CAN)-23 | View |
Pressure and Topical Applications and Treatments – GE(CAN)-25 | View |
TECH NOTES - VERSA-LAM LVL | > |
---|---|
Versa-Lam Allowable Hole Chart – LVL(CAN)-1 | View |
Versa-Stud Allowable Nailing and Notching – LVL(CAN)-2 | View |
Connecting Multiple-Ply Versa-Lam Beams – LVL(CAN)-3 | View |
Connection of Side Point Loads to Triple 1 3/4" VERSA-LAM Beams – LVL(CAN)-4 | View |
Cupping of VERSA-LAM Plies & Beams – LVL(CAN)-5 | View |
Requirements for Use of Simpson Strong-Tie Connectors with Versa-LAM & Versa-Rim Products – LVL(CAN)-6 | View |
Attachment fo Brick Lintel to Versa-Lam Beams – LVL(CAN)-7 | View |
Connecting Multiple-Ply 1 3/4" VERSA-LAM Beams with Simpson Strong-Tie SDS Screws – LVL(CAN)-8 | View |
Connecting Multiple-Ply 1 3/4" VERSA-LAM Beams with FastenMaster TrussLok Screws – LVL(CAN)-9 | View |
Connection of Side Point Loads to Double 1 3/4" VERSA-LAM Beams – LVL(CAN)-10 | View |
Versa-LAM 2.0 3100 Column Table – LVL(CAN)-11 | View |
Installation of Simpson Strong-Tie Connectors Parallel to Gluelines of Versa-Lam Beams & Columns – LVL(CAN)-12 | View |
Versa-LAM 2.0 3100 Column Table (Smaller Depth Columns) – LVL(CAN)-13 | View |
Fire Resistance Rating of VERSA-LAM LVL Columns – LVL(CAN)-15 | View |
Connecting Multiple-Ply VERSA-LAM Beams with Simpson Strong-Tie SDW Strong-Drive Screws – LVL(CAN)-16 | View |
Tall Wall Design Procedures For Versa-Lam LVL – LVL(CAN)-18 | View |
PRODUCT/SPECIFIER/TECHNICAL GUIDES | > |
---|---|
CANADA ENGLISH Versa-Lam® 2.1E 2800 2.1E 3100 West Specifier Guide | View |
CANADA ENGLISH Versa-Lam® 1.8E 2400 1.8E 2650 West Specifier Guide | View |
CANADA ENGLISH Install Guide | View |
CANADA ENGLISH Tall Wall Specifier Guide | View |
CANADA ENGLISH Versa-Lam® 2.3E 3100 West Specifier Guide | View |
CANADA ENGLISH Tall Wall Climatic Data Specifier Guide | View |
TECH NOTES - GENERAL ENGINEERING | > |
---|---|
Weights of Building Materals – GE(CAN)-1 | View |
Flame Spread and Fire Endurance: Surface Coatings – GE(CAN)-2 | View |
Allowable Nail Spacing & Designfor AJS® / BCI® Joists and Versa-L am® LVL – GE(CAN)-3 | View |
BCI / AJS Joist, VERSA-LAM & BOISE GLULAM Exterior Exposure Policy – GE(CAN)-4 | View |
Joist Ceiling Framing Over an Indoor Pool – GE(CAN)-5 | View |
Formaldehyde & Engineered Wood Products – GE(CAN)-15 | View |
Lateral Bracing of Joists and Beams – GE(CAN)-16 | View |
Vertical Load Transfer over Bearings within BC FRAMER & BC CALC – GE(CAN)-23 | View |
Pressure and Topical Applications and Treatments – GE(CAN)-25 | View |
TECH NOTES - VERSA-LAM LVL | > |
---|---|
Versa-Lam Allowable Hole Chart – LVL(CAN)-1 | View |
Versa-Stud Allowable Nailing and Notching – LVL(CAN)-2 | View |
Connecting Multiple-Ply Versa-Lam Beams – LVL(CAN)-3 | View |
Connection of Side Point Loads to Triple 1 3/4" VERSA-LAM Beams – LVL(CAN)-4 | View |
Cupping of VERSA-LAM Plies & Beams – LVL(CAN)-5 | View |
Requirements for Use of Simpson Strong-Tie Connectors with Versa-LAM & Versa-Rim Products – LVL(CAN)-6 | View |
Attachment fo Brick Lintel to Versa-Lam Beams – LVL(CAN)-7 | View |
Connecting Multiple-Ply 1 3/4" VERSA-LAM Beams with Simpson Strong-Tie SDS Screws – LVL(CAN)-8 | View |
Connecting Multiple-Ply 1 3/4" VERSA-LAM Beams with FastenMaster TrussLok Screws – LVL(CAN)-9 | View |
Connection of Side Point Loads to Double 1 3/4" VERSA-LAM Beams – LVL(CAN)-10 | View |
Versa-LAM 2.0 3100 Column Table – LVL(CAN)-11 | View |
Installation of Simpson Strong-Tie Connectors Parallel to Gluelines of Versa-Lam Beams & Columns – LVL(CAN)-12 | View |
Versa-LAM 2.0 3100 Column Table (Smaller Depth Columns) – LVL(CAN)-13 | View |
Fire Resistance Rating of VERSA-LAM LVL Columns – LVL(CAN)-15 | View |
Connecting Multiple-Ply VERSA-LAM Beams with Simpson Strong-Tie SDW Strong-Drive Screws – LVL(CAN)-16 | View |
Tall Wall Design Procedures For Versa-Lam LVL – LVL(CAN)-18 | View |
Versa-Lam LVL is available at dealers across the United States and Canada.
Find a distribution center near you.