Versa-Lam LVL beams are strong throughout, engineered to support heavier loads, and provide longer spans than stock glulams (24F-V4) or dimensional lumber products.
When you need better performance, longer spans, and the best overall value, Versa-Lam® LVL delivers.
Versa-Lam laminated veneer lumber (LVL) beams and headers lead the industry in bending strength and E-value, offering better performance and longer spans. Versa-Lam LVL offers the best overall value across multiple widths and depths for residential, light commercial, or multifamily projects.
Heavy loads? No problem. Longer spans? Don’t give them a second thought. Versa-Lam LVL beams and headers are up to the task.
Versa-Lam LVL Benefits:
|
Versa-Lam LVL beams come in various sizes to accommodate diverse structural requirements. For detailed size charts and span tables, refer to our Western and Eastern Guides in our resources below.
“I would consider Boise Cascade the Tiger Woods of Engineered Wood. It's at the top. And when you lay your head down at night, and you've delivered something like that, you can rest your head and know that you might have a problem, but it won't be with their product.”
Operations Manager - Lumber & Supply Dealer
Versa-Lam LVL beams are strong throughout, engineered to support heavier loads, and provide longer spans than stock glulams (24F-V4) or dimensional lumber products.
Versa-Lam LVL beams and headers won’t twist, shrink, or split, resulting in flatter, quieter floors and strong structures saving time while protecting reputations.
Precision cut into more than 18 standard sizes to match BCI and AJS Joists, with extra-wide widths that eliminate the need for bolting and excessive nailing.
| Title | Resource Type | Share | hf:tax:resource-category | hf:tax:region | |
|---|---|---|---|---|---|
| Multifamily & Light Commercial Promo flyer – MTP-7100 | Multifamily/Light Commercial | View | mflc | us-east us-west canada-east canada-west | |
| Canadian Fire and Design Installation Guide – French – MTP-CF7050 | Multifamily/Light Commercial, Safety & Fire | View | mflc safety-fire | canada-east | |
| BCI Joist and Versa-Lam LVL Installation Guide – East – MTP-E7001 | *Popular, Installation Guide | View | aa-popular installation-guide | us-east | |
| BCI Joist and Versa-Lam LVL Commercial Guide – East – MTP-E7010 | *Popular, Multifamily/Light Commercial | View | aa-popular mflc | us-east | |
| BCI Joist, Versa-Lam LVL and BOISE GLULAM Commercial Guide – West – MTP-W7010 | *Popular, Multifamily/Light Commercial | View | aa-popular mflc | us-west | |
| BCI Joist and Versa-Lam LVL Specifier Guide – East – MTP-E7000 | *Popular, Product / Specifier Guide | View | aa-popular product-specifier-guide | us-east | |
| ESR-1040 Versa-Lam LVL Code Report | Code Report | View | code-report | us-east us-west canada-east canada-west | |
| CCMC 12472E Versa-Lam LVL English Code Report | Code Report | View | code-report | us-east us-west canada-east canada-west | |
| CCMC 12472E Versa-Lam LVL French Code Report | Code Report | View | code-report | canada-east canada-west | |
| BCI Joist and Versa-Lam LVL Specifier’s Guide – West – JOI-W7000 | *Popular, Product / Specifier Guide | View | aa-popular product-specifier-guide | us-west | |
| Fire Design and Installation Guide – MTP-7051 | Multifamily/Light Commercial, Safety & Fire | View | mflc safety-fire | us-east us-west canada-east canada-west | |
| Versa-Lam LVL 2.1E Design Guide – East – LVL-E2000 | *Popular, Product / Specifier Guide | View | aa-popular product-specifier-guide | us-east | |
| Versa-Lam LVL 1.7E 2650 Header Guide – East – LVL-E2003 | Product / Specifier Guide | View | product-specifier-guide | us-east | |
| Versa-Lam LVL 1.7E 2650 Stair Stringer Guide – East – LVL-E2015 | Product / Specifier Guide | View | product-specifier-guide | us-east | |
| Versa-Lam LVL Design Guide – West – LVL-W2000 | *Popular, Product / Specifier Guide | View | aa-popular product-specifier-guide | us-west | |
| Versa-Lam LVL 1.5E 1800 Stair Stringer Guide – West – LVL-W2015 | Product / Specifier Guide | View | product-specifier-guide | us-west | |
| Canadian Versa-Lam LVL 2.1E 3100 Specifier Guide – East – LVL-CE2000 | Product / Specifier Guide | View | product-specifier-guide | canada-east | |
| Canadian Versa-Lam LVL 2.1E 3100 Specifier Guide – French – LVL-CF2000 | Product / Specifier Guide | View | product-specifier-guide | canada-east | |
| Canadian Versa-Lam LVL 2.3E 3100 Specifier Guide – West -LVL-CW2000 | Product / Specifier Guide | View | product-specifier-guide | canada-west | |
| Canadian Versa-Lam LVL 1.8E 2400/2650 Specifier Guide – West – LVL-CW2001 | Product / Specifier Guide | View | product-specifier-guide | canada-west | |
| Canadian Versa-Lam LVL 2.1E 2800/3100 Specifier Guide – West – LVL-CW2002 | Product / Specifier Guide | View | product-specifier-guide | canada-west | |
| BCI Joist and Versa-Lam LVL Installation Guide – West – MTP-W7001 | *Popular, Installation Guide | View | aa-popular installation-guide | us-west | |
| Canadian Versa-Lam LVL, BCI and AJS Joist Installation Guide – French – MTP-CF7001 | Installation Guide | View | installation-guide | canada-east canada-west | |
| Brick Veneer Support on Wood – GE-2 | Tech Note U.S. | View | tech-note-u-s | us-east us-west | |
| Allowable Fastener Spacing & Design for BCI Joists and Versa-Lam LVL – GE-3 | Tech Note U.S. | View | tech-note-u-s | us-east us-west canada-east canada-west | |
| Required Separation Between Garage and Living Space Above – GE-5 | Tech Note U.S. | View | tech-note-u-s | us-east us-west | |
| Designing for Ceramic or Stone Tile Floor Finishes – GE-6 | Tech Note U.S. | View | tech-note-u-s | us-east us-west | |
| Feet & Inches on a Regular Calculator – GE-9 | Tech Note U.S. | View | tech-note-u-s | us-east us-west | |
| Temperature and Moisture Content of Engineered Wood Products During Manufacturing – GE-10 | Tech Note U.S. | View | tech-note-u-s | canada-east canada-west | |
| High Slope Roofs – GE-12 | Tech Note U.S. | View | tech-note-u-s | us-east us-west | |
| Formaldehyde & Engineered Wood Products – GE-15 | Tech Note U.S. | View | tech-note-u-s | us-east us-west | |
| Lateral Bracing of Joists and Beams – GE-16 | Tech Note U.S. | View | tech-note-u-s | us-east us-west | |
| Use of Engineered Wood Products in International Shipping Pallets and Packaging – GE-17 | Tech Note U.S. | View | tech-note-u-s | us-east us-west | |
| Wood Frame Garage Floor Design Guidelines – GE-19 | Tech Note U.S. | View | tech-note-u-s | us-east us-west | |
| Design Load Considerations for Non-Load Bearing Partition Walls in Residential Construction – GE-22 | Tech Note U.S. | View | tech-note-u-s | us-east us-west | |
| Vertical Load Transfer over Bearings within BC FRAMER & BC CALC – GE-23 | Tech Note U.S. | View | tech-note-u-s | us-east us-west | |
| Use of Boise Cascade EWP for Concrete Formwork – GE-24 | Tech Note U.S. | View | tech-note-u-s | us-east us-west | |
| Pressure and Topical Applications and Treatments – GE-25 | Tech Note U.S. | View | tech-note-u-s | us-east us-west | |
| PreserveTech HW / Royal Pacific Industries Insect-Treated Engineered Wood Products for Hawaii – GE-26 | Tech Note U.S. | View | tech-note-u-s | us-east us-west | |
| Electrical Wiring Installation Horizontal Holes – GE-27 | Tech Note U.S. | View | tech-note-u-s | us-east us-west | |
| Installed Damaged Product – GE-28 | Tech Note U.S. | View | tech-note-u-s | us-east us-west | |
| Versa-Lam Allowable Hole Chart – LVL-1 | Tech Note U.S. | View | tech-note-u-s | us-east us-west canada-east canada-west | |
| Versa-Stud Allowable Nailing and Notching – LVL-2 | Tech Note U.S. | View | tech-note-u-s | us-east us-west | |
| Connecting Multiple-Ply Versa-Lam Beams – LVL-3 | Tech Note U.S. | View | tech-note-u-s | us-east us-west canada-east canada-west | |
| Connection of Side Point Loads to Triple 1 3/4″ VERSA-LAM Beams – LVL-4 | Tech Note U.S. | View | tech-note-u-s | us-east us-west canada-east canada-west | |
| Cupping of Versa-Lam LVL Plies & Beams – LVL-5 | Tech Note U.S. | View | tech-note-u-s | us-east us-west canada-east canada-west | |
| Requirements for Use of Simpson Strong-Tie Connectors with Versa-LAM & Versa-Rim Products – LVL-6 | Tech Note U.S. | View | tech-note-u-s | us-east us-west | |
| Attachment of Brick Lintel to Versa-Lam Beams – LVL-7 | Tech Note U.S. | View | tech-note-u-s | us-east us-west canada-east canada-west | |
| Connecting Multiple-Ply 1 3/4″ Versa-Lam LVL Beams with Simpson Strong-Tie SDS Screws – LVL-8 | Tech Note U.S. | View | tech-note-u-s | us-east us-west | |
| Connecting Multiple-Ply 1 3/4″ Versa-Lam LVL Beams with FastenMaster TrussLok Screws – LVL-9 | Tech Note U.S. | View | tech-note-u-s | us-east us-west canada-east canada-west | |
| Connection of Side Point Loads to Double 1 3/4″ Versa-Lam LVL Beams – LVL-10 | Tech Note U.S. | View | tech-note-u-s | us-east us-west | |
| Versa-Lam LVL 2.0 3100 Column Table – LVL-11 | Tech Note U.S. | View | tech-note-u-s | us-east us-west | |
| Installation of Simpson Strong-Tie Connectors Parallel to Gluelines of Versa-Lam LVL Beams & Columns – LVL-12 | Tech Note U.S. | View | tech-note-u-s | us-east us-west canada-east canada-west | |
| Versa-Lam LVL 2.0 3100 Column Table (Smaller Depth Columns) – LVL-13 | Tech Note U.S. | View | tech-note-u-s | us-east us-west canada-east canada-west | |
| Connection of Side Point Loads to Quadruple 1 3/4″ Versa-Lam LVL Beams – LVL-14 | Tech Note U.S. | View | tech-note-u-s | us-east us-west canada-east canada-west | |
| Fire Resistance Rating of Versa-Lam LVL Columns – LVL-15 | Tech Note U.S. | View | tech-note-u-s | us-east us-west canada-east canada-west | |
| Connecting Multiple-Ply Versa-Lam LVL Beams with Simpson Strong-Tie SDW Strong-Drive Screws – LVL-16 | Tech Note U.S. | View | tech-note-u-s | us-east us-west | |
| Alternate Power and Hand Driven Nailing of Multiple Ply 1 3/4″ Wide Versa-Lam LVL Beams – LVL-17 | Tech Note U.S. | View | tech-note-u-s | us-east us-west canada-east canada-west | |
| 2 1/2″ Versa-Lam LVL 1.7 2650 Joists Residential Floor Span Tables – LVL-18 | Tech Note U.S. | View | tech-note-u-s | us-east us-west canada-east canada-west | |
| Concentrated Side Load Connections in BC Calc – Multi-Ply Versa-Lam LVL Beams – LVL-19 | Tech Note U.S. | View | tech-note-u-s | us-east us-west | |
| Versa-Lam LVL Beam Allowable Reactions with End Bevel Cuts – LVL-20 | Tech Note U.S. | View | tech-note-u-s | us-east us-west | |
| Versa-Lam LVL Allowable Hole Chart – LVL(CAN)-2 | Tech Note Canada | View | tech-note-canada | ||
| Versa-Stud Allowable Nailing and Notching – LVL(CAN)-2 | Tech Note Canada | View | tech-note-canada | canada-east canada-west | |
| Connecting Multiple-Ply Versa-Lam LVL Beams – LVL(CAN)-3 | Tech Note Canada | View | tech-note-canada | canada-east canada-west | |
| Ripping Versa-Lam LVL – LVL(CAN)-4 | Tech Note Canada | View | tech-note-canada | canada-east canada-west | |
| Cupping of Versa-Lam LVL Plies & Beams – LVL(CAN)-5 | Tech Note Canada | View | tech-note-canada | canada-east canada-west | |
| 2-Ply Versa-Lam LVL Headers Separated by a 1 ¾” Gap – LVL(CAN)-6 | Tech Note Canada | View | tech-note-canada | canada-east canada-west | |
| Attachment of Brick Lintel to Versa-Lam LVL Beams – LVL(CAN)-7 | Tech Note Canada | View | tech-note-canada | ||
| Multi-Ply Connections for Versa-Stud and Versa-Lam Columns – LVL(CAN)-8 | Tech Note Canada | View | tech-note-canada | canada-east canada-west | |
| Connecting Multiple-Ply 1 3/4″ Versa-Lam LVL Beams with FastenMaster TrussLok Screws – LVL(CAN)-9 | Tech Note Canada | View | tech-note-canada | canada-east canada-west | |
| Versa-Lam LVL Multiple Beam Side Load FlatLOK Connections – LVL(CAN)-10 | Tech Note Canada | View | tech-note-canada | canada-east canada-west | |
| Versa-Lam LVL 2.0 3100 Column Table – LVL(CAN)-11 | Tech Note Canada | View | tech-note-canada | canada-east canada-west | |
| Installation of Simpson Strong-Tie Connectors Parallel to Gluelines of Versa-Lam LVL Beams & Columns – LVL(CAN)-12 | Tech Note Canada | View | tech-note-canada | canada-east canada-west | |
| Versa-Lam LVL Ledger Fastening (SDWS Screws) – LVL(CAN)-13 | Tech Note Canada | View | tech-note-canada | canada-east canada-west | |
| Fire Resistance Rating of Versa-Lam LVL Columns – LVL(CAN)-15 | Tech Note Canada | View | tech-note-canada | canada-east canada-west | |
| Weights of Building Materials – GE(CAN)-1 | Tech Note Canada | View | tech-note-canada | canada-east | |
| Flame Spread and Fire Endurance: Surface Coatings – GE(CAN)-2 | Tech Note Canada | View | tech-note-canada | canada-east | |
| Allowable Nail Spacing & Design for AJS and BCI Joists and Versa-Lam LVL – GE(CAN)-3 | Tech Note Canada | View | tech-note-canada | canada-east | |
| Joist Ceiling Framing Over an Indoor Pool – GE(CAN)-5 | Tech Note Canada | View | tech-note-canada | canada-east | |
| Formaldehyde & Engineered Wood Products – GE(CAN)-15 | Tech Note Canada | View | tech-note-canada | canada-east | |
| Lateral Bracing of Joists and Beams – GE(CAN)-16 | Tech Note Canada | View | tech-note-canada | canada-east | |
| Vertical Load Transfer over Bearings within BC FRAMER & BC CALC – GE(CAN)-23 | Tech Note Canada | View | tech-note-canada | canada-east | |
| Pressure and Topical Applications and Treatments – GE(CAN)-25 | Tech Note Canada | View | tech-note-canada | canada-east canada-west | |
| 1 1/2″ Versa-Lam LVL 1.7 2650 Joists Residential Floor Span Tables – LVL-18 | Tech Note U.S. | View | tech-note-u-s | us-east us-west | |
| Attachment of Brick Lintel to Versa-Lam LVL Beams – LVL-7 | Tech Note U.S. | View | tech-note-u-s | us-east us-west | |
| BCI and AJS Joist, Versa-Lam LVL & BOISE GLULAM Exterior Exposure Policy – GE-4 | Tech Note U.S. | View | tech-note-u-s | us-east us-west | |
| Connecting Multiple-Ply 1 3/4″ Versa-Lam Beams with FastenMaster TrussLok Screws – LVL-9 | Tech Note U.S. | View | tech-note-u-s | us-east us-west | |
| Connecting Multiple-Ply Versa-Lam LVL Beams – LVL-3 | Tech Note U.S. | View | tech-note-u-s | us-east us-west | |
| Connection of Side Point Loads to Triple 1 3/4″ Versa-Lam LVL Beams – LVL-4 | Tech Note U.S. | View | tech-note-u-s | us-east us-west | |
| Cupping of Versa-Lam Plies & Beams – LVL-5 | Tech Note U.S. | View | tech-note-u-s | us-east us-west | |
| Versa-Lam 2.0 3100 Column Table (Smaller Depth Columns) – LVL-13 | Tech Note U.S. | View | tech-note-u-s | us-east us-west | |
| Weights of Building Materials – GE-1 | Tech Note U.S. | View | tech-note-u-s | us-east us-west | |
| Versa-Lam LVL vs Steel Beam Conversions – LVL(CAN)-18 | Tech Note Canada | View | tech-note-canada | canada-east canada-west | |
| Weights of Building Materials – GE(CAN)-1 | Tech Note Canada | View | tech-note-canada | canada-east | |
| BCI and AJS Joist, Versa-Lam LVL and BOISE GLULAM Exterior Exposure Policy – GE(CAN)-4 | Tech Note Canada | View | tech-note-canada | canada-east | |
| Versa-Lam LVL Allowable Hole Chart – LVL(CAN)-1 | Tech Note Canada | View | tech-note-canada | canada-east canada-west | |
| Attachment of Brick Lintel to Versa-Lam LVL Beams – LVL(CAN)-7 | Tech Note Canada | View | tech-note-canada | canada-east canada-west | |
| Tall Wall Design Procedures For Versa-Lam LVL – LVL(CAN)-16 | Tech Note Canada | View | tech-note-canada | canada-east canada-west | |
| Canadian Versa-Lam LVL, BCI and AJS Joist Installation Guide – MTP-C7001 | *Popular, Installation Guide | View | aa-popular installation-guide | canada-east canada-west | |
| Versa-Lam LVL Product Overview – LVL-2010 | Product Flyer | View | product-flyer | ||
| Versa-Lam LVL Stair Stringer Product Overview – LVL-2011 | Product Flyer | View | product-flyer | ||
| Flame Spread Classifications – GE-13 | Tech Note U.S. | View | tech-note-u-s | ||
| Versa-Lam LVL 1.8E Wide Rimboard Product Overview – LVL-2013 | Product Flyer | View | product-flyer | ||
| Versa-Lam LVL Rimboard Product Overview – LVL-2012 | Product Flyer | View | product-flyer | ||
| VLT Panel Product Overview – MAS-5250 | Mass Timber, Multifamily/Light Commercial, Product Flyer | View | mass-timber mflc product-flyer | ||
| Reinforcement of Boise Cascade Floor Framing Supporting Guards – IJ-36 | Tech Note U.S. | View | tech-note-u-s | ||
| Mass Timber Solutions Guide – MAS-5200 | Mass Timber, Product / Specifier Guide | View | mass-timber product-specifier-guide | ||
| Mass Timber Specifier Design Guide – MAS-5201 | Mass Timber, Product / Specifier Guide | View | mass-timber product-specifier-guide |
Versa-Lam LVL is available at dealers across the United States and Canada.
Find a distribution center near you.